Patient Monitoring System-manufacture,factory,supplier from China

(Total 24 Products for Patient Monitoring System)
Product descriptionThe 4K medical endoscope camera system is compatible with multiple professions, including surgical endoscopy, urology, gynecology, orthopedics, and otolaryngology.With the help of 4K technology, we are striving to improve the visibility of endoscopes even better than open surgery by adding features such as ultra-high definition, wider color gamut, and enlarged visualization.Technical Parameter1.TV system: PAL2.
Contacter maintenant
Product DescriptionAnesthetic Gas Scavenging System (AGSS) is a device used to remove anesthetic gases generated in operating rooms or other medical environments.Anesthetic gas is a medication used during surgery, usually delivered to patients through an anesthesia machine.However, some anesthesia gases may leak into the air of the operating room, posing potential health risks to medical staff and patients.The main function of AGSS is to collect and discharge anesthesia gases from the operating room through inhalation and filtration,in order to reduce the risk of personnel exposure to these ga
Contacter maintenant
Product descriptionBuilt in 8'' color anaesthesia ventilatorNew compact CO2 absorber(autoclavable,Patent)high end precise vaporizer(volume>280ml,Patent)Battery back up for all system over 60 mins,bain circuit interfaceOptional:Touch screen anaesthesia ventilatorOptional:Anaesthesia gas scavenging systemOptional:Yoke system,electronic tidal volume(Innovation)Optional:Continuous FIO2 monitoring, EtCO2 monitoring functionOptional:Built-in air compressor or Air/O2 inter-link system(innovation)Technical ParameterProduct nameModel no. MOQ Q'ty MeasurementG.W.
Contacter maintenant
Product descriptionLigasure is also called high frequency surgical system, and ligasure is widely used in various surgical operations. Compared with traditional electrosurgical equipment, ligasure has the function of cutting blood coagulation and sealing 7 mm large blood vessels.FAQQ1. What is the advantage about your company?A1.The company has been engaged in export business for more than 15 years, with a professional team and professional production line.Q2.
Contacter maintenant
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
Contacter maintenant
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
Contacter maintenant
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
Contacter maintenant
Product DescriptionUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring(REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,laparoscope and other endoscopes.Support bipolar closure and separation to meet the reguirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality detect
Contacter maintenant
Product descriptionExperts have identified harmful smoke which contain toxic gases and vapors will occurduring electrosurgical operation.Medical staff and patients exposure to the smoke may cause viral contamination,respiratory problems and burning eyes.To use a smoke evacuation system is themost effective way of protecting operating room staff and patients from hazard.The smoke evacuator is easy to operate and easy to replace filters.
Contacter maintenant
Product descriptionThe anesthesia evaporator combines the characteristics of ergonomics, accuracy, safety, and reliability. Precision design will provide reliable and safe solutions for the filling and installation types of anesthesia machines.Adopting the latest innovative design of the conveying system, the vaporizer can deliver accurate concentrations under different flow rates, pressures, temperatures, and other conditions.The carburetor is calibrated by skilled technicians.
Contacter maintenant
Product Description1. 7" screen displays information area, alarm area, monitoring area, and setting area. 2. High precision mechanical flowmeter, instantly know the fresh gas flow to animals. 3. Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime. 4. Real time pressure-time, flow-time oscillogram 5. Manual and mechanical ventilation for safer operation.6. External sensor design makes parameters setting more accurate. 7.
Contacter maintenant
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
Contacter maintenant
Product descriptionRemote fault diagnosis.Human voice alarm function.Full-function automatic power compensation.System has return electrode monitoring (REM) system.Microprocessor control and digital display in LED panel.Used for Monopolar and Bipolar surgery in many surgical fields.Support bipolar closure and separation to meet the requirements of surcical bipolar treatment withoutsticking the negative plate.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.This machine has a power-off protection circuit, which
Contacter maintenant
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
Contacter maintenant
IntroductionAnaesthesia main unit:High resolution 5.5''  LCD screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarming:Low O2 gas pressure,it will give alarming more than 7 secondsHigh pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Low pressure protection:Once O2 pressure less than 0.1MPa, N2O gas supply was stoppedautomatically.Power failure alarming, power extendable function02 flush: 25~75 L/minGas
Contacter maintenant
Product DescriptionScope of ApplicationIt is suitable for various surgeries on cutting or coagulation, including general surgery, heart, urology, gynecology, anorectal surgery, orthopedics, thoracic surgery, tumor, etc. It is also used with surgeries of endoscope, hysteroscope, laparoscope, ENT endoscope, etc. The bipolar can be used in the fine surgeries of microsurgery, neurology, ENT and ophthalmology, hand surgery,etc.Product Details●Independent output port of endoscope and intelligent conversion key, which can enter endoscopic mode automatically after start-up.
Contacter maintenant
Procuct descriptionThis transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contacter maintenant
Product description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations.
Contacter maintenant
Product DescriptionVeterinary anesthesia systems are widely used in veterinary clinics, hospitals and laboratories and continue to be well received by customers around the world.The SD-M2000A(P) model is designed for safe, simple, and controlled inhalation anesthesia in animals. Veterinary anesthesia systems provide rapid control of depth of anesthesia, low respiratory resistance, acuity from high to low, simple to complex cases, small to large animals such as dogs, cats, rabbits, mice, birds, etc.Technical SpecificationAnaesthesia main unit:Working Mode: ManualWorking method: Close,
Contacter maintenant
Product descriptionSD-M2000A(P) Veterinary anesthesia machines are reliable professional equipment for small animal anesthesia. Easy installation and maintenance, saving space.
Contacter maintenant
Product Description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations. During first aid and transport, even in the event of a power outage, it can help patients maintain normal respiratory function and prevent dangerous situationscaused by insufficient oxygen.FAQQ1.What are your packaging details?A1.
Contacter maintenant
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contacter maintenant
Product descriptionAnaesthesia main unit:High luminance digital LED screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarm: O2 gas pressure is low, alarm time exceeds 7 secondsHigh pressure limit: Whenever the airway pressure exceeds the preset high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Power failure alarming,power extendable functionO2 flush:25~75L/minGas Pressure:O2:0.3~0.5MPaPower:220V±10%, 50Hz±1%Technology specificationFlow meter:O2 - dual tube(0.05~1L/min,1.1~10L/min
Contacter maintenant
Product descriptionThe 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as biological tissue cutting and coagulation, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.The output of this machine is fully suspended, with two independently isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, non-APG type general equipment, 220V±10% or 110V±10% network power supply.Technology parameterRated out
Contacter maintenant
Relate News
Model30 Anesthesia MachineBuilt in 5.5" anaesthesia ventilator, bain circuit interfaceHigh end precise vaporizer (Volume > 280ml, Patent)New compact CO2 absorber (autoclavable, Patent)Battery back up for all system over 60 minsHigh brightness LED lighting systemOptional: Anaesthesia gas scavenging systemOptional: Electronic anaesthesia vaporizer (Patent)Optional: Yoke system, Electronic tidal volume (lnnovation)Optional: Continuous FIO2 monitoring, EtCO2 monitoring functionOptional: Built-in air compressor Or Air/O2 inter-link system (lnnovation)
Anaesthesia Machine MODEL40Built in 8"color anaesthesia ventilatorNew compact CO2 absorber (autoclavable, Patent)High end precise vaporizer (Volume > 280ml, Patent) Battery back up for all system over 60 mins, bain circuit interfaceOptional: Touch screen anaesthesia ventilatorOptional: Anaesthesia gas scavenging systemOptional: Electronic anaesthesia vaporizer (Patent)Optional: Yoke system, Electronic tidal volume (Innovation)Optional: Continuous FIO2 monitoring, EtCO2 monitoring functionOptional: Built-in air compressor Or Air / O2 inter-link system (lnnovation)
The Difference between ESU and Ultrasonic Surgery SystemThe principle of electrosurgical unit cutting is to generate voltage and current at the tip of the electric knife, and generate high temperature when in contact with the skin to cut tissue.The application principle of ultrasonic knife is to convert electrical energy into mechanical energy through a special conversion device, and the mechanical energy transmitted in the form of sine waves acts on the metal knife head at the front end, causing the knife head to produce 50-100 μ.The mechanical oscillation of m amplitude generates frictional
The Working Mode of Electrosurgical Unit1. Monopolar modeIn the monopole mode of the Electrosurgical Unit, a complete circuit is used to cut and solidify tissue, which consists of a high-frequency generator inside the high-frequency electric knife, patient electrode plates connected to wires, and electrodes. In most applications, current passes through the patient through effective wires and electrodes, and then returns to the generator of the high-frequency electric knife through the patient's electrode plate and connecting wires.2.
Introduction to Anesthesia Machine Evaporator      The anesthesia evaporator is an important component of the anesthesia machine, and its quality not only indicates the level of the anesthesia machine, but also relates to the success or failure of inhalation anesthesia, directly affecting the safety of the patient.
HUIFA has attended EWSA Veterinary conference 2023, details as following fyi:Fair name: EWSA Veterinary conference 2023Date: May 23- May 25Location: Qingdao International Convention and Exhibition CenterBooth number: Hall 3 H17Exhibition products: veterinary anesthesia machine, anesthesia ventilator, electrosurgical unit,Ultrasonic scaple system, portable laptop endoscopy, 4K ultra HD endoscopy tower, patient monitor, infusion pump, syringe pump, ICU oxygen chamber etc.Welcome to be our honored partners.HUIFA
The Purpose of Anesthesia Machine     Theanesthesia machine is not only suitable for general anesthesia, but also can assist the breathing of critically ill patients during anesthesia. It can also be combined with other anesthetic drugs to perform compound anesthesia in different forms.(1) Definition and significance of anesthesia    The broad definition of anesthesia is to cause the patient to temporarily lose all or part of the pain sensation.
CM-350C Electrosurgical UnitUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring (REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.Support bipolar closure and separation to meet the requirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality de
Characteristics of Emergency Transport Ventilator      Many people believe that emergency transport ventilators are equivalent to simple ventilators, because compared to professional ICU therapeutic ventilators, emergency transport ventilators do not have as many ventilation modes and parameter monitoring in terms of mode function. However, in fact, professional emergency transport ventilators should have the following major characteristics (which cannot be achieved by large ICU ventilators):       Portability:1. Small in size and light in weight.
SD-M2000B Anaesthesia MachineCompact design, save space in O.R.or Laboratory RoomBuilt in 5.5”LCD Anaesthesia ventilatorNew compact CO2 absorber (autoclavable, Patent)High precise big volume vaporizerOptional: Bain circuit interface, Continuous FIO2 monitoringOptional: Battery back up for all system not less than 60 mins
x

Soumis avec succès

nous vous contacterons dès que possible

Fermer